Common array manager software.

2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and

Common array manager software. Things To Know About Common array manager software.

Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using the Sun Storage Common Array Manager software, version 6.9.0.Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur.As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.Note - For other arrays managed by the Sun StorageTek Common Array Manager, firmware, this release may require special firmware instructions. Refer to the Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 (or later) for the latest firmware information and a list of firmware files for your array.

Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …

The array management software configures both physical and logical storage components. The components of a storage array configuration are as follows. Initiator - A port on a Fibre Channel (FC) host bus adapter (HBA) that allows a host to gain access to the storage array. The initiator has a World Wide Name (WWN) that is globally unique.As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.

Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... The array management software saves the configuration to allow access control between the specified SAS ports and targets. 7. Click Export to save the configuration to a template (see the Online Help for more information about creating SAS Access Configuration templates. ... Sun Storage Common Array Manager saves the current SAS domain ...Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, a "preferred controller" and an ...2 Sun StorageTek Common Array Manager Software 6.4 Release Notes • April 2009 About Sun StorageTek Common Array Manager Software The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM …The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su -

SANtricity Storage Manager. SANtricity ES Storage Manager 10.77 Software and Array Documentation l. SANtricity Storage Manager 8.3x l. Sun Storage Common Array Manager Software. Sun Storage Common Array Manager 6.10 l. Sun Storage Common Array Manager 6.9 l.

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options … Common Array Manager Software Features. The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek storage arrays. Uninstall all previous versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.0 release. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet port of either array controller. Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle’s Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0_20 product release. 5. If needed, change the array management default IP addresses using the serial port interface. Configuring IP Addressing. 6. Install the Sun StorageTek Common Array Manager software. 7. In the software, register the storage array and perform the basic administration setup. Note: for storage array configuration, use the iSCSi steps that follow.5. From the Oracle Java Web Console page, select Sun Storage Common Array Manager from the Storage section of the Oracle Java Web Console page. Providing Site Information. When you open the Common Array Manager after a first-time installation, the General Configuration page displays. 1. Enter the required site and contact information for your site.

See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.Sun Storage 2530-M2 Array - Version Not Applicable and later All Platforms Goal. This document describes the significance of a volume's "owning controller" and "preferred controller", and also explains how to change the "owning controller" setting of an individual volume via the Sun Storage Common Array Manager software.Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle’s Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0_20 product release.Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit …As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。.

Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. ... Instead, you use the management software provided with the Unified Storage System. Please refer to J4200/J4400 Array System Overview. Solution. …

Common Array Manager Software Features. The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek storage arrays. See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …The purpose of this document is to provide an easily accessible reference for the supported browsers and operating systems for Sun Storage Common Array Manager (CAM), version 6.10. Scope Please refer to the page for Sun Storage Common Array Manager Software 6.10 Documentation on the Oracle Technology Network for complete information …Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, ...Common Array Manager Software Features The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 6.0.1 iSCSI support for Sun StorageTek 2510 Array Minimal (CLI-only) installation 3. Install the desired version of the Common Array Manager software as described in the Installation Guide in the doc directory of the software installation CD or download. Note –The procedure will be similar to “Installing the Common Array Manager Software” on page 7, but the prior release may have differences. 4.

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …

This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links.

Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another might require special procedures. The Sun StorageTek Common Array Manager Software Installation Guide is a combined software installation and initial configuration guide. This guide describes how to install management and configuration software, and how to perform initial storage planning and configuration. Consult the hardware installation guide for your array Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit …Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. The Sun StorageTek Common Array Manager Installation Software CD provides three installation-related wizards: GUI software installer - Enables you to use a graphical user …Download popular programs, drivers and latest updates easily Sun Storage Common Array Manager Online Help is a software that provides a simple, unified interface for managing Sun Storage arrays. It simplifies deployment, simplifies the storage environment, and increases utilization. The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU identification and ... Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Dec 31, 2014 · Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count ... Service Advisor integrated with the Sun StorageTek Common Array Manager software. Reference information for the CLI Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this

Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using ... As part of the installation of the Common Array Manager software, the script puts the array firmware files in a directory on the management host. When you upgrade the firmware, the software analyzes the firmware installed on the array. If the firmware on the host is newer, and you choose to install, the software installs the firmware on the array.Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count: Unlimited. Permitted Uses: You may reproduce and use the Software for Your own Individual, Commercial, or Research and Instructional Use, subject to and conditioned on.Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Instagram:https://instagram. stair climber workoutrussian to english translation keyboardcustomise chrome browsergoogle docs timeline template See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. hoteisconference call free number How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM. Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using ... doodle scheduler Software Release Notes, Release 6.10 Update for Solaris OS Hosts September 2015 Review important late-breaking information about Sun Storage Common Array Manager 6.10 Update.Dell Array Manager is storage management software that provides Array, Disk, Volume and Enclosure management functions. Through a common interface Array Manager let's you configure and manage local and remote storage attached to your system while your system remains online. Dell Array Manager is a software tool for installing and …CAM is a software application that allows you to manage SAS-NEMs. and disk blades in a chassis from one central point. It is written. in Java so you can run it on any platform. …